Modeling Requirements

This document describes the hardware modeling requirements for PlatformManager configuration.

PMUnit

Unit used for modeling in PlatformManager. It typically matches with a FRU, but not always. PMUnit and FRU terminologies are used interchangeably in this document. PMUnit and FRU differences will be explicitly called out when they are not interchangeable.

What is modeled as PMUnit

  • Any unit which has an IDPROM (e.g., PSU, SCM, SMB).
  • Any unit which does not have an IDPROM and can be field swapped and does not have any devices like I2C, FPGA, CPLD, SPI, EEPROM etc. (e.g., FanTray).

What is not modeled as PMUnit

  • Any unit which does not have an IDPROM and cannot be field swapped.
  • If such a unit has no devices (I2C, FPGA, CPLD, etc.), then it does not need modeling in PlatformManager.
  • If such a unit has devices (I2C, FPGA, CPLD, etc.), then it will be modeled as part of another PMUnit (referred to as hosting PMUnit). This is one case where one PMUnit could model multiple FRUs together. In this case, when the device is re-spun, the IDPROM of the hosting PMUnit MUST be updated to reflect the re-spin (e.g. product version/sub-version number change). It should also include IDPROM changes of the hosting PMUnit.

PlatformManager Flowchart

EEPROM

It should store content in Meta EEPROM V6 format.

IDPROM

  • Any EEPROM which is used to identify the FRU/PMUnit type is called IDPROM.
  • The IDPROM in the FRU MUST be connected in one of the following ways:
    • Directly to an incoming I2C bus from the parent FRU.
    • Directly to the CPU's SMBus I2C Controller.
  • The Product Name field in the IDPROM should have the corresponding PMUnit name used in the PlatformManager configuration as the value.
  • The Product Name should not be cryptic or in code words. The Product Name should be obvious about the functionality of the PMUnit. Some examples:
    • Use SCM for a PMUnit containing CPU (not EAGLE or PLATFORM_NAME_SCM)
    • Use SMB for a PMUnit containing the switch ASIC.
    • Use PSU for Power Supply Unit
    • Use FAN for FAN PmUnit
    • PDB, MCB, JUMPER, FCB etc., are other valid names
  • Chassis EEPROM is not considered an IDPROM.

Chassis EEPROM

  • Chassis EEPROM will be modeled as just an ordinary EEPROM (within the containing PMUnit).
  • Chassis EEPROM should be a dedicated EEPROM. It MUST NOT also serve as a FRU/PMUnit IDPROM described above.
  • The Product Name field of the Chassis EEPROM must be the platform name. It must be the same as the output of dmidecode -s system-product-name.

Field-Replaceability

  • The unit must be a PMUnit (FRU) for it to be field-replaceable.

Re-Spin

  • Any respin of a PMUnit, should involve update of the IDPROM of that PMUnit.
  • Any respin of a non-PMUnit, should be bundled with changes in IDPROM of a hosting PMUnit.
  • The same platform config will be used for both re-spun and original platform. For the PMUnit which has difference across re-spin and original platform, the platform config will have two definitions of the PMUnit - one each for re-spin and original platform. Hardware Version will be used as a key to look up the right PMUnit config.

Example configuration for re-spin:

{
"pmUnitConfigs": {
"SMB": [
{
"productProductionState": 0,
"productVersion": 1,
"productSubVersion": 0,
"i2cDeviceConfigs": { ... }
},
{
"productProductionState": 0,
"productVersion": 2,
"productSubVersion": 0,
"i2cDeviceConfigs": { ... }
}
]
}
}

PlatformManager reads the IDPROM to determine which PMUnit config to use.

  • IDPROM content difference for the PMUnit across respins is a combination of the below three keys in IDPROM:
    • Product Production State
    • Product Version
    • Product Sub-Version

PMUnit IDPROM I2C Addressing

PMUnits of the same slot type should have the same address for the IDPROM. For example, all PIM8DD and PIM16Q PMUnits, which are of slot type PIM, should have the same address for their IDPROM. This enables these PMUnits to be plugged into any PIM slot and be discovered by PlatformManager.

I2C Devices

All I2C devices should be connected in one of the following ways:

  • Directly to an incoming I2C bus from a parent PMUnit
  • Directly to a MUX or FPGA present within the PMUnit (or containing PMUnit)
  • Directly to the CPU's SMBus I2C Controller

PMUnit Presence

PMUnit presence bits must be managed by the chips present in the parent PMUnit.

Root PmUnit

This is the PmUnit which is used by Platform Manager as the starting node for Platform exploration. The choice of root PmUnit should ensure all the above conditions are met.